REINFORCEKiT® 1D

Prepreg System for Pipe Protection and Reinforcement

Product Sheet

REINFORCEKiT® 1D (R1D) is a water activated prepreg system, wrapped helicoidally around the pipe to restore its original integrity without shutdown.

REINFORCEKiT® 1D repairs and reinforces pipes suffering from corrosion and mechanical damages. This composite product is made of fiber glass and polyurethane resin.

REINFORCEKiT® 1D can also be used as protection for coated pipes.

In case of reinforcement application, the product must be used with specific 3X filler and primer. The repair design and material requirements are provided by 3X software, according to ISO 24.817 & ASME PCC-2.

In case of protection application, only R1D prepreg tape is necessary. 3X recommends to apply a minimum of 2 layers.

USES

  • Reinforce pipe suffering from:
    • External/Internal corrosion
    • Mechanical damage
  • Restore pipe original integrity
  • Impact protection
  • Coating protection

APPLICATIONS

  • Onshore and offshore installations
  • All pipe diameters (no limitation)
  • All pipe geometries including welds, elbows and tees
  • Compatible with most common fluid and gas
  • Temperature up to +68°C (for reinforcement use) and up to +88°C (for protection use)

BENEFITS

  • Online repair (no shutdown required)
  • Fast and easy implementation
  • Long-term performance
  • No heating or post-curing required

Use PIPE REINFORCEMENT & COMPOSITE REPAIR FOR EXTERNAL/INTERNAL CORROSION
Pipe diameter No limitation
Application temperature From +10°C (+50°F) to +68°C (+154°F)
Max and Min operating temperatures for reinforcement use From -50°C (-58°F) to +68°C (+154°F)
Max and Min operating temperatures for protection use From -50°C (-58°F) to +88°C (+190°F)

Designed as per ISO 24.817 & ASME PCC-2
Surface preparation Sa2½ / St3 and roughness Rz > 60 µm​
Filler and primer application​
R1D wrapping (spray water continuously)​
Identification plate positionning​
Compression film application and perforation​

For reinforcement application, steps 1 to 6

For protection application, only steps 4-5-6

3X recommends to apply an anti-UV coating after R1D installation