Case Studies

R4D, 178 joint sections suffering from internal damages – Qatar

HIGH-PERFORMANCE COMPOSITE REPAIR SOLUTION FOR PIPE REINFORCEMENT DEFECT TYPE 178 joint sections suffering from internal damages DETAILS PIPES DETAILS: 2inch piping spools– Sour Water– design temp. 85°C – design pressure 30.5 barg LOCATION QATAR 3X PRODUCT REINFORCEKiT® 4D OVERVIEW The objective of the repair, carried out by PEC team (Power Engineering Corp. / Alqodara Alhandaseya  […]

R4D, 178 joint sections suffering from internal damages – Qatar Read More »

REINFORCEKiT® PATCH, deck reinforcement – Vietnam

UNUSUAL DECK REINFORCEMENT DEFECT TYPE External corrosion DETAILS Deck reinforcement – max. op. temp. 40°C LOCATION VIETNAM, Onboard FPSO Armada TGT1 3X PRODUCT REINFORCEKiT® PATCH OVERVIEW The objective of the repairs, performed by 3X ENGINEERING (3X) local distributor PETROENERTECH, was to reinforce the main deck onboard FPSO Armada TGT1 suffering from external damages metal loss

REINFORCEKiT® PATCH, deck reinforcement – Vietnam Read More »

R4D, Internal corrosion pittings – Qatar

HIGH-PERFORMANCE COMPOSITE REPAIR SOLUTION FOR PIPE REINFORCEMENT DEFECT TYPE Internal corrosion pittings DETAILS PIPES DETAILS: ¾ straight piping lines – oil – design temp. 74°C – design pressure 144 barg LOCATION QATAR 3X PRODUCT REINFORCEKiT® 4D OVERVIEW The objective of the repair, performed by 3X ENGINEERING (3X) local distributor POWER ENGINEERING CORPORATION (PEC), was to

R4D, Internal corrosion pittings – Qatar Read More »

R4D, External corrosion and hole – Rajasthan, WEST INDIA

HIGH-PERFORMANCE COMPOSITE REPAIR SOLUTION FOR PIPE REINFORCEMENT DEFECT TYPE External corrosion and hole DETAILS PIPES DETAILS: 18”, 22”, 24”, 30” and 36” pipelines – oil and gas – temperature 70°C – design pressure from 3 to 17bars LOCATION Rajasthan, WEST INDIA 3X PRODUCT REINFORCEKiT® 4D OVERVIEW The objective of the repairs, started by 3X INDIA,

R4D, External corrosion and hole – Rajasthan, WEST INDIA Read More »

STOPKiT®, Online leak sealing system installation in bank data centre – Colombia

ONLINE LEAK SEALING SOLUTION FOR EMERGENCY PIPE REPAIR DEFECT TYPE Online leak sealing system installation in bank data centre with refrigeration system LOCATION COLOMBIA 3X PRODUCT STOPKiT® OVERVIEW The objective of this job, performed by 3X ENGINEERING (3X) distributor in Colombia – C.P.S, was to train onsite technical team of a bank data center to

STOPKiT®, Online leak sealing system installation in bank data centre – Colombia Read More »

R4D-S, External corrosion and leak in subsea environment – Middle East

HIGH-PERFORMANCE COMPOSITE REPAIR SOLUTION FOR PIPE REINFORCEMENT DEFECT TYPE External corrosion and leak in subsea environment DETAILS 48” oil line – max. op. temp. 25°C – calculated pressure 17.85 bars LOCATION MIDDLE EAST 3X PRODUCT REINFORCEKiT® 4D Subsea (R4D-S) OVERVIEW The objective of the repair, performed by 3X ENGINEERING (3X) and its local distributor, was

R4D-S, External corrosion and leak in subsea environment – Middle East Read More »

REINFORCEKiT® PATCH Norway

EMERGENCY COMPOSITE REPAIR SOLUTION FOR TANK AND PRESSURE VESSEL REINFORCEMENT DEFECT TYPE Hole defect DETAILS TANK DETAILS: 47” gas separator – max op. temperature 60°C – calculated pressure 10 bar LOCATION NORWAY 3X PRODUCT REINFORCEKiT® PATCH OVERVIEW The objective of the repair, performed by 3X ENGINEERING (3X) Specialists and FUGLESANGS (3X local distributor), was to

REINFORCEKiT® PATCH Norway Read More »

R4D-S, subsea dent – Vietnam

HIGH-PERFORMANCE COMPOSITE REPAIR SOLUTION FOR PIPE REINFORCEMENT DEFECT TYPE subsea dent DETAILS 16” gas line – max. op. temp. 45°C – calculated pressure 93 bars LOCATION VIETNAM 3X PRODUCT REINFORCEKiT® 4D Subsea (R4D-S) OVERVIEW The objective of the repair, performed by 3X ENGINEERING (3X) local distributor PETROENERTECH, was to reinforce a 16” subsea pipe with

R4D-S, subsea dent – Vietnam Read More »